THINK SAW,THINK STRONG!

PRODUCTS


Product Introduction

F8986 Micro Flow Sensor

Principle Introduction:
Strong First Electronics produces F8986 micro flow sensor, adopting thermodynamic principle to detect the gas flow.
F8986 micro flow sensor adopts thermodynamic principle to detect the gas flow, and it has high accuracy and good repeatability. The built-in temperature sensor makes the product has the function of professional temperature compensation calibration. At the same time, the output is linear analog voltage which is convenient to use.
Applications :
Industrial process control
Air and environment protection
Technical parameters :

Model F8986
Measuring Range① 20、30、50、100、200、500、1000、1200、2000sccm②
  Min Typical Max Unit
Full Scale Output 4.90 5.00 5.10 V
Zero Output 0.96 1.00 1.04 V
Output Impedance - 200 - Ω
Working Voltage 7.0 10.0 14.0 V
Working Current 15 25 30 mA
Accuracy - ±1.5 ±2.5 %F.S
Repeatability - ±0.3 ±0.5 %F.S
Annual Drift③ - ±0.1 ±0.5 %F.S
Pressure range④ - - 200 kPa
Response Time 5 10 15 ms
Working Temp.⑤ -25   65
Storage Temp. -40   90


Note:
①The measuring range within 20-2000sccm is available and regular measuring ranges such as 20、30、50、100、200、500、1000、1200、2000sccm.
②sccm means standard-state cubic centimeter per minute. Standard-state: gas temperature is 0℃ and pressure is 101.325 kPa.
③The testing environment is room temperature and clear air.
④The pressure range of 1 MPa can be customized.
⑤The temperature compensation is for the tem. range of 0-50℃ and the compensation performance can’t be ensured beyond the temperature range.

>>