ZPH98 Particles Sensor-Manual

Principle Introduction:
This sensor adopts advanced PM2.5 detection technology to detect PM2.5. PM2.5 detection adopts particle counting principle to detect the particles (diameter ≥1μm).
Before delivery, the sensor has been aged, debuged, calibrated and has good consistency and high sensitivity. It has the PWM signal output, and it can be configured to be UART digital serial interface and customized IIC interface.
Applications :
Air refresher, air conditioner, ventilating device, monitor equipment for environment, smoke alarm &etc.
Technical parameters :

Model ZPH98
Working voltage range 5±0.2 V DC
Output PWM /UART
Detection ability for PM2.5 particles ≥1 μm diameter
Warm-up time ≤5min
Detection Range for particles 15000 particles /283ml
Working Current ≤150mA
Humidity range Storage ≤90%RH
Working ≤90%RH
Temperature range Storage -20℃~50℃
Working 0℃~50℃
Size 59.47×44.5×20mm
Physical interface EH2.54-5P

>>