MC886C Catalytic Flammable Gas Sensor/C3H8 Sensor/Methane Gas Sensor

Principle Introduction:
Strong First Electronics, MC886C adopts catalytic combustion principle, and detects natural gas CH4, LPG C3H8, CO and alkanes.
MC886C adopts catalytic combustion principle, and its two arms of electric bridge consists of a test element and a compensate element. The resistance of the test element rises once it meets the combustible gases, in the same time, the output voltage of the bridge changes and the voltage variation rises in direct proportion to the gas concentration. The compensate element, as a conference, has the function of compensating temperature and humidity.
Applications :
It is widely used in industrial occasion to detect the concentration of natural gas, LPG, CO and alkanes.
It is also used in combustible gas leakage alarm system, combustible gas detector and gas concentration meter and so on.
Technical parameters :

Model MC886/ MC886C
Sensor Type Catalytic
Standard Encapsulation Metal, Metallurgy powder mesh
Working voltage(V) 2.8±0.1
Working current(mA) MC113: 90±10; MC113C: 95±10
Sensitivity (mV) 1% CH4 MC113: 20 to 40; MC113C: 16 to 35
1% C3H8 MC113: 30 to 60; MC113C: 25 to 55
Linearity ≤5%
Measuring range(%LEL) 0 to 100
Response Time (90%) ≤10s
Recovery Time (90%) ≤30s
Working Environment -40 to +70℃, less than 95%RH
Storage Environment -20 to +70℃, less than 95%RH
Size (mm) MC113: 19×9.5×14; MC113C: 14×8×10
Anti-explosion Mark ExdibⅠ

>>